Refrivanta HVAC System Service

R407C 25LB Refrigerant Cylinder

R407C refrigerant for professional servicing of compatible air conditioning, heat pump, and medium-temperature refrigeration systems that require R407C. Confirm the equipment nameplate and service documentation before purchasing.

25 lb / 11.3 kg ASHRAE A1 R32 / R125 / R134a Blend Section 608 Required
Professional service only. Use only in equipment specifically approved for R407C.
R407C 25 pound refrigerant cylinder
25LB Net weight / 11.3 kg
A1 Lower toxicity / no flame propagation
1774 Global warming potential (AR4)
0 Ozone-depletion potential
R407C quick specifications and physical properties

Technical profile

R407C quick specifications

R407C is an HFC refrigerant blend commonly used in compatible air conditioning, heat pump, and medium-temperature refrigeration systems. It is also used as an R22 replacement option in properly evaluated retrofit applications.

Use only in systems whose manufacturer documentation identifies R407C as the required refrigerant. R407C must never be mixed with another refrigerant or used as a drop-in substitute without manufacturer approval.

Chemical blend R32 / R125 / R134a
Blend ratio 23 / 25 / 52 wt%
Safety class A1
Primary use A/C and refrigeration service

Cylinder details

Sealed and clearly identified

The steel service cylinder contains 25 lb / 11.3 kg net weight of R407C refrigerant and is supplied with a sealed valve for professional handling.

  • One sealed R407C refrigerant cylinder
  • 25 lb / 11.3 kg refrigerant net weight
  • Approx. 16.5 inches high and 9.8 inches wide
  • Non-refillable professional service cylinder
R407C cylinder packaging, sealed valve and dimensions
Common applications for existing compatible R407C systems

Compatible applications

Where R407C is commonly used

R407C may be used to service compatible air conditioning, heat pump and refrigeration equipment designed for R407C operating requirements. It should only be used when the equipment label identifies R407C as the required refrigerant.

01 Residential A/C Systems

Home air-conditioning units and split systems designed or properly retrofitted for R407C.

02 Commercial HVAC Systems

Compatible rooftop units, packaged systems and commercial cooling equipment.

03 Refrigeration Equipment

Medium-temperature refrigeration systems that specifically require R407C service.

Professional service

Made for certified technicians

R407C service must be performed by an appropriately certified technician using approved recovery, charging, leak-check and retrofit procedures when applicable.

Follow the cylinder label, current safety data sheet, equipment manufacturer instructions and all applicable federal, state and local requirements.

  • Verify R407C on the equipment nameplate before use
  • Section 608 certification is required for stationary equipment
  • Recover refrigerant—never knowingly vent refrigerant
  • Never mix R407C with another refrigerant
Certified HVAC technician servicing compatible existing R407C equipment

Refrivanta Support Center

R407C Product FAQs

Clear answers about R407C compatibility, EPA certification, shipping, cylinder weight, retrofit use, storage and delivery concerns.

01 Is this R407C refrigerant factory sealed?

Yes. This R407C refrigerant is supplied in a factory-sealed service cylinder. The original seal should remain intact until the cylinder is opened by a trained technician for approved service use.

02 How do I know if R407C is compatible with my system?

Check the equipment nameplate, service manual and manufacturer specifications. Use R407C only when the equipment is specifically identified for R407C, or when a qualified technician confirms the system is properly approved for R407C retrofit use.

R407C is an HFC blend commonly used for compatible A/C, heat pump and refrigeration systems, including some properly evaluated R22 retrofit applications. Do not mix it with another refrigerant or treat it as a universal drop-in replacement.
03 Do I need EPA certification to purchase R407C?

R407C for stationary air-conditioning and refrigeration equipment is subject to EPA Section 608 sales restrictions. Eligible buyers generally include Section 608-certified technicians, businesses that employ a properly certified technician, and qualified resellers.

Refrivanta may request certification, employer authorization or resale documentation before processing an order.

04 Is R407C the same as R22 or a direct drop-in replacement?

No. R407C is an HFC blend, not R22, and it should not be treated as an automatic direct drop-in replacement. Some systems may use R407C only after a proper retrofit evaluation and approved service procedure.

Oil type, metering device, charge amount, system labels, leak condition and manufacturer guidance should all be checked by a qualified technician before using R407C in retrofit service.

05 How quickly will my R407C order ship?

Orders are normally processed within one business day. Standard delivery is generally estimated at 2–5 business days after carrier pickup. Weekend and public-holiday orders are processed on the next business day.

Multiple cylinders may ship separately. Delivery estimates can be affected by carrier routing, weather, hazardous-material requirements and address restrictions.

06 Why does the shipping label show a different weight?

A carrier label may display estimated, preset, dimensional or billing weight. This can differ from the product’s 25 lb / 11.3 kg refrigerant net weight because the cylinder and shipping packaging add weight.

If you have a concern after delivery, keep the cylinder unopened and contact us with your order number and clear photos of the cylinder and shipping label.

07 How should I store and handle an R407C cylinder?

Follow the cylinder label and current safety data sheet. Keep the cylinder upright, secured and in a cool, dry, well-ventilated area away from direct sunlight, excessive heat and ignition sources.

R407C is pressurized and can create serious exposure hazards. Handling and system service should be performed by a trained, appropriately certified technician using suitable tools and personal protective equipment. Never intentionally vent refrigerant.

08 What should I do if the cylinder is damaged, leaking or missing?

Do not connect, use or attempt to repair a cylinder that appears damaged, punctured or leaking. Keep people away, avoid heat and ignition sources, and contact local emergency services if there is an immediate hazard.

For visible shipping damage, contact Refrivanta when safe with your order number and clear photos. If tracking shows delivered but the shipment is missing, check the delivery photo, entrances, garage, front desk, mailroom and nearby properties before contacting us.

Email support@refrivanta.com with the order and tracking numbers, or call +1 (825) 360-9654.

Still need help?

Contact Refrivanta customer care with your order or R407C product details.